A common approach to BOM generation is to export the BOM data from Altium NEXUS, into a company-preferred Excel format spreadsheet. The BOM is generated from the Report Manager, which can be accessed from:

  • ActiveBOM's Report menu
  • The schematic and PCB editor's Report menu
  • A BOM Report Output configured in an OutputJob
  • Learn more about BOM Configuration in the Report Manager.
  • For complete control over the BOM configuration process, including an interactive view of supply chain information as well as custom BOM rows and columns, add an ActiveBOM document (BomDoc) to your project. The BomDoc gives instant visibility into the component supply chain and also supports user-defined rows and columns, ideal for including those extra items, such as glue, labels, and so on. Creating and managing the BOM through a BomDoc is the recommended approach to BOM Management in Altium NEXUS.

The Report Manager's Export Options includes two XLS File Format options:

  • MS-Excel (*.xls, *.xlsx) - requires Microsoft Excel
  • Generic XLS (*.xls, *.xlsx) - uses a built-in XLS file generator, Microsoft Excel is not required

Select the required Excel file format option, then select the required Excel template

When an Excel option is selected a pre-defined Excel template can then be selected in the Template dropdown. When the Export button is clicked in the Report Manager the BOM data is generated and loaded into a new Excel Worksheet, using the format defined in the chosen Excel template.

The list of templates available in the drop down comes from:

  • For an unmanaged design, the default location is configured in the Data Management - Templates page of the Preferences dialog. Several example templates are included, in the \Templates folder of the installation user-files.
  • For a managed design, the available templates are stored in the \Templates\BOM Templates folder of your managed content server.

How Design Data is Mapped in the Excel Template

Altium NEXUS data is mapped into the spreadsheet by including special Field and Column statements in the Excel template. The Field statement is used to map a single parameter, for example a document parameter called Title. The Column statement is used to map per-component parameters, for example the Designator component parameter.

Fields

The Field statement is used to map a document or project parameter, for example the Title, into the BOM. The Field declaration is replaced by the passed value, as shown in the images below.

Fields are used in the format:

Field=FieldName

An example would be Field=Currency

Fields should be defined above or below the Column region of the template.

Columns

Column declarations are used to map per-component parameters, for example each component's Designator, Description, user-defined parameters, and so on. This can also include: line numbers, PCB location data, and custom column data entered into the BomDoc, if there is a BomDoc in the project. The Column declaration in the template is replaced by the ColumnName string, with each row below being populated by that column value for each BOM Item, as shown in the two images below.

Columns are used in the format:

Column=ColumnName

An example would be Column=Designator

Notes:

  • Each column defined in the template must be displayed in the Report Manager, for that column of data to be transferred.
  • The data will present in the Excel spreadsheet in the same row order that it has in the Report Manager. Use the Report Manager's column sorting and sub-sorting feature to sort the rows as required.

Example of a simple Excel template, showing how the design parameters are mapped into the template

Example of a BOM created from the simple Excel template shown in the previous image

  • Several example templates are included with Altium NEXUS, in the \Templates folder of the installation user-files.
  • The default template location for an unmanaged design is configured in the Data Management - Templates page of the Preferences dialog.
  • For a managed design, the available templates are stored in the \Templates\BOM Templates folder of your managed content server.

Mapping Project-Level, BOM Header Information

Project-level information is typically mapped using the Field= statement, into the header of the BOM document.

Field Description
Currency The currency chosen in the Supplier Options region of the Report Manager dialog.
DataSourceFileName The filename of the source used for the BOM data.
DataSourceFullPath The full path + filename of the source used for the BOM data.
GeneratorDescription For a BOM, this field displays Bill of Materials.
GeneratorName Name of the generator - BOM when output is generated by the Report Manager.
OutputName Title of the BOM, as displayed in the Report Manager (excluding the text "For BOM Document [<DataSourceFileName>]").
OutputType For a BOM, this field displays BOM_PartType.
PCBDataSourceFileName The filename of the PCB data source.
ProductionQuantity Production quantity defined in the Report Manager dialog.
ProjectFileName Name of the PrjPcb file (including file extension).
ProjectFullPath Full path + the project filename.
ReportDate Date on which the report was created.
ReportDateTime Date and time at which the report was created.
ReportTime Time at which the report was created.
TotalQuantity Sum of the values in the BOM Items Quantity column.
Title Title displayed at the top of the BOM Reports dialog.
VariantName Name of the variant, as defined in the Variant Management dialog.
VersionControl_RevNumber Current revision of the BomDoc.
VersionControl_ProjFolderRevNumber Current revision of the project (incremented when a Commit Whole Project is performed).
<UserProjectParameter_n> Displays the value assigned to the user-defined UserProjectParameter-n.

Mapping Document and Project Parameters

As well as the Field statements listed above, schematic Document Parameters (both default and user-defined parameters entered in the schematic document's Properties panel) and Project Parameters (Options for PCB Project dialog) can also be used as Fields, or as Columns.

Address1 Address2 Address3
Address4 ApprovedBy Author
CheckedBy CompanyName ConfigurationParameters
CurrentDate CurrentTime Date
DocumentFullPathAndName DocumentName DocumentNumber
DrawnBy Engineer ImagePath
Index ModifiedDate Organization
Revision Rule SheetNumber
SheetTotal Time  

If the same parameter exists as both a document parameter and a project parameter, the project parameter takes precedence. If the same document parameter exists in multiple documents, the document parameter that is higher up in the heirarchy takes precedence.

Mapping BOM Item Information

The core region of a BOM is the grid of BOM Items, typically using a row for each component. Each column in this grid represents a component property, such as the designator, value, and so on. Columns are defined by entering the component property/parameter (BOM column heading), in the format:

Column=ColumnName

An example would be Column=Description, or Column=Designator

Column information can be taken from several sources, including:

These ColumnNames are available for all components

Comment ComponentKind Description
Designator DesignItemId Footprint
LibRef LogicalDesignator PartType
PhysicalPath Quantity UniqueIdName
UniqueIdPath <UserParameter_n>  

PCB component location information can also be included. In order to use these columns, the Include Parameters From PCB option must be enabled in the Report Manager dialog.

Center-X(Mil) Center-Y(Mil) Center-X(mm) Center-Y(mm)
Pad-X(Mil) Pad-Y(Mil) Pad-X(mm) Pad-Y(mm)
Ref-X(Mil) Ref-Y(Mil) Ref-X(mm) Ref-Y(mm)
Layer Rotation    

It is possible to retrieve online data from suppliers, and include that into the BOM. Note that these are updated live, and are retrieved when the BOM is generated. Multiple suppliers can be set up for each component. In the table below, these have been described as Supplier Info x - replace x with the appropriate number.

Manufacturer x Manufacturer Part Number x Supplier x
Supplier Currency x Supplier Order Qty x Supplier Part Number x
Supplier Stock x Supplier Subtotal x Supplier Unit Price x

User-defined columns are includes in the same way:

Column=ColumnName

 

 

Found an issue with this document? Highlight the area, then use Ctrl+Enter to report it.

お問合せ

お近くの営業所にお問合せください。

You are reporting an issue with the following selected text
and/or image within the active document:
Altium Designer 無償評価版
Altium Designer 無償評価版
Altium Designerを使用していますか?

弊社の営業担当より詳細情報をご案内しますので、アルティウムジャパン までお問い合わせください。.
Copyright © 2019 Altium Limited

評価版ライセンスが必要な理由を下記から選択してください。

弊社の営業担当より詳細情報をご案内しますので、アルティウムジャパン までお問い合わせください。.
Copyright © 2019 Altium Limited

その場合、評価版ライセンスは不要です。

ボタンをクリックして、最新のAltium Designerインストーラをダウンロードしてください。

Altium Designerインストーラをダウンロードする

弊社の営業担当より詳細情報をご案内しますので、アルティウムジャパン までお問い合わせください。.
Copyright © 2019 Altium Limited

Altium Designerの新規ライセンスのお見積もりをご希望の場合、下記のフォームに入力してください。

プライバシーポリシーに同意の上、[ダウンロード]をクリックしてください。ご登録いただきましたメールアドレスにメールマガジンが送信されます。メール配信の停止は、メール内の​通知設定​​でお手続きいただけます。

Altium Designerサブスクリプションをご利用中の場合、評価版ライセンスは不要です。

お客様がAltium Designerサブスクリプションの有効なメンバーではない場合、下記のフォームに入力して無償評価版をダウンロードしてください。

プライバシーポリシーに同意の上、[ダウンロード]をクリックしてください。ご登録いただきましたメールアドレスにメールマガジンが送信されます。メール配信の停止は、メール内の​通知設定​​でお手続きいただけます。

Altium Designerを評価する理由を下記から選択してください。

弊社の営業担当より詳細情報をご案内しますので、アルティウムジャパン までお問い合わせください。.
Copyright © 2019 Altium Limited

無償評価版を使用するには、下記のフォームに入力してください。

プライバシーポリシーに同意の上、[ダウンロード]をクリックしてください。ご登録いただきましたメールアドレスにメールマガジンが送信されます。メール配信の停止は、メール内の​通知設定​​でお手続きいただけます。

Great News!

Valid students can get their very own 6-month Altium Designer Student License for FREE! Just fill out the form below to request your Student License today.

プライバシーポリシーに同意の上、[ダウンロード]をクリックしてください。ご登録いただきましたメールアドレスにメールマガジンが送信されます。メール配信の停止は、メール内の​通知設定​​でお手続きいただけます。

その場合、Altium Designerビューワーの無償ライセンス(有効期間6か月)をダウンロードできます。

下記のフォームに入力してライセンスをリクエストしてください。

プライバシーポリシーに同意の上、[ダウンロード]をクリックしてください。ご登録いただきましたメールアドレスにメールマガジンが送信されます。メール配信の停止は、メール内の​通知設定​​でお手続きいただけます。

素晴らしいですね。アルティウムではモノづくりに最適なプログラムを提供しています。

Upverterは、コミュニティ主導型の無償プラットフォームで、お客様のような作り手の要求に合わせて設計されています。

試してみる場合、こちらをクリック してください。

弊社の営業担当より詳細情報をご案内しますので、アルティウムジャパン までお問い合わせください。.
Copyright © 2019 Altium Limited

その場合、Altium Designerビューワーの無償ライセンス(有効期間6か月)をダウンロードできます。

下記のフォームに入力してライセンスをリクエストしてください。

プライバシーポリシーに同意の上、[ダウンロード]をクリックしてください。ご登録いただきましたメールアドレスにメールマガジンが送信されます。メール配信の停止は、メール内の​通知設定​​でお手続きいただけます。