Query_Lang-SCHFunctions_MembershipChecks_Object_HasModelParameterObject_HasModelParameter_AD

This document is no longer available beyond version 21. Information can now be found here: Object_HasModelParameter for version 24

Applies to Altium Designer version: 21

Parent page: Schematic Query Functions - Membership Checks

Summary

Returns all child objects of each part object that is linked (or references) a domain model, containing a parameter object whose Parameter Name and Value properties comply with the Query.

Each part can be linked to models of Footprint, Simulation, Ibis, FPGA Pin, and Signal Integrity types. It is possible to link a part to more than one model of the same type, but only one model of each type can be selected as a part's Current Model.

Syntax

Object_HasModelParameter(Parent,Parameter Name : String,Value : String,CurrentModelOnly : Boolean) : Boolean/Boolean_String

The CurrentModelOnly parameter specifies whether or not the linked model (which contains a compliant parameter) has to be a Current Model of each part. When this is False, the linked model does not have to be a Current Model (but it still can be); when this is True, the linked model does have to be a Current Model.

Example Usage

Object_HasModelParameter(Parent,'Inductance A','1mH',False)
Object_HasModelParameter(Parent,'Inductance A','1mH',False) = True
Object_HasModelParameter(Parent,'Inductance A','1mH',False) = 'True'

Returns all child objects of part objects that are linked to a model that contains a parameter object whose Parameter Name property is Inductance A, and whose Value property is 1mH. That model does not have to be a Current Model of each Part (but it can be).

Object_HasModelParameter(Parent,'Coupling Factor','0.999',True)
Object_HasModelParameter(Parent,'Coupling Factor','0.999',True) = True
Object_HasModelParameter(Parent,'Coupling Factor','0.999',True) = 'True'

Returns all child objects of part objects that are linked to a model that contains a parameter object whose Parameter Name property is Coupling Factor, and whose Value property is 0.999. That model must be a Current Model of the Part.

 

Примечание

Доступные функциональные возможности зависят от вашего уровня Подписки на ПО Altium Designer.