Working with the Signal Stimulus Design Rule on a PCB in Altium Designer

您正在阅读的是 19.0. 版本。关于最新版本,请前往 Working with the Signal Stimulus Design Rule on a PCB in Altium Designer 阅读 21 版本
 

Rule category: Signal Integrity

Rule classification: Unary

Summary

This rule specifies the characteristics of the stimulus signal used when performing a signal integrity analysis on the design. This is the signal that is injected at each output pin on the net under test. The worst-case result is returned during design rule checking.

All design rules are created and managed within the PCB Rules and Constraints Editor dialog. For a high-level view of working with the design rules system, see Defining, Scoping & Managing PCB Design Rules.

Constraints

Default constraints for the Signal Stimulus rule.Default constraints for the Signal Stimulus rule.

  • Stimulus Kind - specifies the type of stimulus signal that is injected during signal integrity analysis. The following stimulus types are available:
    • Constant Level - the stimulus signal remains at a constant voltage - either High or Low - depending on the chosen Start Level option
    • Single Pulse - the stimulus signal is a single pulse, whose characteristics are defined by the Start Level, Start Time and Stop Time options
    • Periodic Pulse - the stimulus signal is a continuous pulse train, whose characteristics are defined by the Start Level, Start Time, Stop Time and Period Time options.
  • Start Level - specifies the voltage level used for the Constant Level stimulus signal, or the initial voltage level for the pulse-based stimulus signals. The following levels are available:
    • Low Level - defined as the LOW level voltage for the output pin - dependent on the model used for the pin
    • High Level - defined as the HIGH level voltage for the output pin - dependent on the model used for the pin.
  • Start Time (s) - the start time for a pulse-based stimulus signal. Used in calculating the width of the pulse.
  • Stop Time (s) - the stop time for a pulse-based stimulus signal. Used in calculating the width of the pulse.
  • Period Time (s)the time between pulses in a periodic pulse train stimulus signal. After the period time has elapsed, another identical pulse of width Stop Time - Start Time is injected.

How Duplicate Rule Contentions are Resolved

All rules are resolved by the priority setting. The system goes through the rules from highest to lowest priority and picks the first one whose scope expression matches the object(s) being checked.

Rule Application

Batch DRC and during Signal Integrity analysis.

Note

When performing a Crosstalk analysis, an Aggressor net will be injected with the stimulus defined in the Stimulus design rule, the LOW and HIGH levels of which are dependent on the model used for the driving output pin. A Victim net will get a Constant Low level voltage injected into it, with the level again being dependent on the model used for the output pin.

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.

软件的功能取决于您购买的Altium产品级别。您可以比较Altium Designer软件订阅的各个级别中包含的功能,以及通过Altium 365平台提供的应用程序所能实现的功能。

如果您在软件中找不到某个讨论过的功能,请联系Altium销售团队以获取更多信息。

Content