WorkspaceManager_Err-MismatchedHiddenPinConnectionsMismatched Hidden Pin Connections_AD

您正在阅读的是 16.1. 版本。关于最新版本,请前往 WorkspaceManager_Err-MismatchedHiddenPinConnections((Mismatched Hidden Pin Connections))_AD 阅读 21 版本
 

Parent category: Violations Associated with Components

Default report mode:

Summary

This violation occurs in multi-part components, where a hidden pin common to more than one sub-part is connected to different nets.

Notification

If compiler errors and warnings are enabled for display on the schematic (enabled on the Schematic - Compiler page of the Preferences dialog) an offending object will display a colored squiggle beneath it. A notification is also displayed in the Messages panel in the following format:

Mismatched hidden pin connections in Pin <Identifier> and Pin <Identifier>

where:

  • Identifier is used to identify the pin in question. The identifier appears in the format PhysicalComponentName-PinDesignator (e.g. U2-7).

Recommendation for Resolution

Reassign the offending pin(s) to the correct nets. Edit the pin(s) using the Component Pin Editor dialog - accessed from the Component Properties dialog by clicking the Edit Pins button. From the Component Pin Editor dialog, access the Logical tab of the Pin Properties dialog for the offending pin (for each sub-part in turn) and check/modify the net entry in the Connect To field.

 

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.

软件的功能取决于您购买的Altium产品级别。您可以比较Altium Designer软件订阅的各个级别中包含的功能,以及通过Altium 365平台提供的应用程序所能实现的功能。

如果您在软件中找不到某个讨论过的功能,请联系Altium销售团队以获取更多信息。

Content