WorkspaceManager_Err-OffGridObjectOff-Grid Object_AD

您正在阅读的是 16.0. 版本。关于最新版本,请前往 WorkspaceManager_Err-OffGridObject((Off-Grid Object))_AD 阅读 21 版本
 

Parent category: Violations Associated with Others

Default report mode:

Summary

This violation occurs when an object is not aligned to the current Snap grid.

Notification

If compiler errors and warnings are enabled for display on the schematic (enabled on the Schematic - Compiler page of the Preferences dialog) an offending object will display a colored squiggle beneath it. A notification is also displayed in the Messages panel in the following format:

Off grid <ObjectIdentifier> at <Location>

where:

  • ObjectIdentifier identifies the specific object that is currently off-grid. The identifier is composed of the object's type and its name/designator (e.g. Pin <PinDesignator>).
  • Location is the X,Y coordinates for the object's electrical hotspot.

Recommendation for Resolution

Ensure that the Snap grid is enabled on the Sheet Options tab of the Document Options dialog (Design » Document Options). The offending object can be moved back onto grid manually, or by using the Edit » Align » Align To Grid command.

 

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.

软件的功能取决于您购买的Altium产品级别。您可以比较Altium Designer软件订阅的各个级别中包含的功能,以及通过Altium 365平台提供的应用程序所能实现的功能。

如果您在软件中找不到某个讨论过的功能,请联系Altium销售团队以获取更多信息。

Content