Applied Parameters: None
Summary
This command is used to load design rule constraint tolerances, where applicable, from the PCB design document into the PCB Design Check/Fix dialog of the current CAM document.
Access
This command is accessed from the CAMtastic Editor by choosing the Analysis » Re-load DRC Rules from PCB command from the main menus.
Use
After launching the command, the relevant design rule tolerances from the PCB document will be loaded into the Size (mils) column of the PCB Design Check/Fix dialog. The mapping of PCB design rule types to the corresponding DRC entries in the PCB Design Check/Fix dialog, are as follows:
Defined PCB Design Rule: |
Maps to CAM DRC Check: |
Minimum Annular Ring |
Min. Annular Ring (Drill->Pad) |
Solder Mask Expansion |
Min. Annular Ring (Pad->Mask) |
Clearance |
Min. Clearance (Pad->Pad) |
Clearance |
Min. Clearance (Pad->Trace) |
Clearance |
Min. Clearance (Trace->Trace) |
Width |
Min. Trace Width |
Minimum Solder Mask Sliver |
Solder Bridging |
Minimum Solder Mask Sliver |
Silkscreen Over Mask |