Signal Integrity - Signal Top Value
Created: March 23, 2017 | Updated: September 26, 2019
| Applies to versions: 18.0, 18.1, 19.0, 19.1, 20.0, 20.1 and 20.2
Now reading version 19.1. For the latest, read: Signal Integrity - Signal Top Value for version 21
Rule category: Signal Integrity
Rule classification: Unary
Summary
This rule specifies the minimum voltage level that a signal can settle to in the high state (the top value).
Constraints
- Minimum (Volts) - the value for the minimum permissible top value voltage.
How Duplicate Rule Contentions are Resolved
All rules are resolved by the priority setting. The system goes through the rules from highest to lowest priority and picks the first one whose scope expression matches the object(s) being checked.
Rule Application
Batch DRC and during Signal Integrity analysis.