StopLayer
Created: October 31, 2018 | Updated: October 31, 2018
| Applies to versions: 18.0, 18.1, 19.0, 19.1, 20.0, 20.1 and 20.2
Now reading version 19.1. For the latest, read: StopLayer for version 21
Parent page: PCB Query Functions - Fields
Summary
Returns all via objects whose right-hand layer in their Drill Pair property complies with the Query.
Syntax
StopLayer = Layer_String
Example Usage
StopLayer = 'Top Layer'
Returns all via objects whose Drill Pair property has a right-hand entry of Top Layer
.
StopLayer <> 'Signal Layer 2'
Returns all objects except for via objects whose Drill Pair property has a right-hand entry of Signal Layer 2
.
IsVia && Stop
Layer <> 'Internal Plane 1
'
Returns all Via objects except those whose Drill Pair property has a right-hand entry of Internal Plane 1
.
Tips
- The single quote characters (') at the start and end of
Layer_String
are mandatory. - The Drill Pair property is only defined for via objects.