Defining the Layer Stack

Now reading version 1.0. For the latest, read: Defining the Layer Stack for version 5

Nexus message

This documentation page references Altium NEXUS/NEXUS Client (part of the deployed NEXUS solution), which has been discontinued. All your PCB design, data management and collaboration needs can now be delivered by Altium Designer and a connected Altium 365 Workspace. Check out the FAQs page for more information.

 
The PCB is designed and formed as a stack of layers. In the early days of printed circuit board (PCB) manufacturing, the board was simply an insulating core layer, clad with a thin layer of copper on one or both sides. Wiring was formed in the copper layer(s) as conductive traces by etching away (removing) unwanted copper.

A simple, single-sided PCB. Note how the circuit tracks on the bottom layer are visible through the board.
A simple, single-sided PCB. Note how the circuit tracks on the bottom layer are visible through the board.

Fast forward to today, where almost all PCB designs have multiple copper layers. Two to 10 copper layers are common, but it is possible to fabricate a board with over 30 copper layers. These copper layers are defined in the design environment as part of the layer stack, along with the insulation material that separates them.

To design a single printed circuit board, it is only necessary to define a single layer stack, which defines the entire board area in the vertical direction, or Z plane. However, technological innovation and refinements in the processing technology have led to a number of revolutionary concepts in PCB fabrication including the ability to design and manufacture flexible PCBs. By joining rigid sections of PCB together via flexible sections, complex, hybrid PCBs can be designed that can be folded to fit into unusually shaped enclosures.

Rigid sections of PCB connected via flexible sections of PCB – an innovative concept that supports the design of creative and compact electronic products.
Rigid sections of PCB connected via flexible sections of PCB – an innovative concept that supports the design of creative and compact electronic products.

Since it is fabricated as a single entity, a rigid-flex PCB must be designed as a single entity. To do this, the designer must be able to define multiple PCB layer stacks and assign different layer stacks to different parts of the rigid-flex design.

PCB Layer Stackup Technology and Terminology

PCB technology has been driven not only by the quest for smaller electronic products, a leading driver of PCB technology has been the quest for more compact components to use in those products.

A limiting factor in how small a component can be made is the challenge of providing access to the component interconnects, or pins, that were traditionally arranged around the edges of the component. The greatest jump in the density of the interconnects came with the introduction of grid array interconnects - where the component's connection points are arranged in rows along the bottom surface of the component. Component packages, such as PGA (Pin Grid Array) and BGA (Ball Grid Array), use this arrangement of interconnects.

An example of the internal structure of a Ball Grid Array package.
An example of the internal structure of a Ball Grid Array package.

Within the component, the silicon die may still present its connection points around the edge of the die, so these die connection points must be internally routed to the grid array of interconnections on the bottom of the PGA or BGA package. This is often done using an internal PCB. It is this internal PCB that has driven much of the High Density Interconnect (HDI) technology development that is now available for use in the broader printed circuit board design and fabrication market.

An excellent reference for building a good understanding of the materials and techniques of both the design and the fabrication of printed circuits is Right First Time - a Practical Handbook on High Speed PCB and System Design, by Lee Ritchley. A free PDF version can be downloaded from http://www.thehighspeeddesignbook.com/.

A Single Design with Multiple Layer Stacks

Main article: Rigid-Flex Design

Like a simple, rigid PCB, a rigid-flex PCB is fabricated as a single entity. To do this, you must be able to:

  • Define the overall shape of the rigid-flex PCB.
  • Define a master set of layers that includes all layers needed in the rigid-flex design.
  • Define multiple layer stacks, where each stack includes only the layers needed for each of the rigid and flexible zones of the PCB.
  • Define the different rigid and flexible zones where each sub-stack is applied.
  • Generate detailed output fabrication and documentation files needed to fabricate the rigid-flex PCB.

This board has had three layer stacks defined, two Rigid stacks and one Flex stack.
This board has had three layer stacks defined, two Rigid stacks and one Flex stack.

Defining the Layer Stack in the Layer Stack Manager

Dialog article: Layer Stack Manager

All layer stacks are defined in the Layer Stack Manager. To open the Layer Stack Manager select Design » Layer Stack Manager from the main menus. For a new board, its single default stack comprises a dielectric core, two copper layers, and the top and bottom solder/coverlay and overlay layers as shown in the image below.

The Layer Stack Manager is used to define the board structure in the vertical, or Z direction. Defining the board in the horizontal, or X-Y direction, is done by first defining the overall board shape. If it is a rigid-flex design, the shape is then divided into the required zones or board regions. Once the board regions have been defined, each region is assigned a layer stack.

Layer stack management is performed in the Layer Stack Manager dialog. The default single stack for a new board is shown.
Layer stack management is performed in the Layer Stack Manager dialog. The default single stack for a new board is shown.

The dialog has two modes. In its Simple mode (shown above), the dialog provides the features and functionality needed to manage the layers in the single stack required in a traditional rigid PCB.

For rigid-flex PCBs, you need to be able to create and manage multiple stacks. This is performed by entering the dialog's Advanced mode by clicking the Advanced button at the bottom-left of the dialog.

Controls for adding and managing stacks are made available by entering the dialog's Advanced mode, which displays the lower region of the dialog.
Controls for adding and managing stacks are made available by entering the dialog's Advanced mode, which displays the lower region of the dialog.

In this mode, the dialog is visually and functionally divided into two key regions:

  • Stack region (the lower region) – use to add, delete, name, and re-order layer stacks.
  • Layer region (the upper region) – use to manage the layers available in each of the defined stacks (add, remove, enable/disable, and re-order layers, as well as define each layer's properties).

The stack currently selected in the lower region of the dialog has its name highlighted and the stack is displayed in the upper layer region of the dialog. To enable or disable layers in a stack, first select the required stack.

The set of available layers and the defined layer stacks can be transferred from one board design to another by clicking the Save button to write them to a *.stackup file. Click the Load button to replace the current set of available layers and defined stacks, with those defined in an external *.stackup file.

Adding, Removing and Configuring the Layer Stacks

Stacks are added, removed, and their order is configured in the lower half of the Layer Stack Manager. Note that this section is only displayed if the Advanced button has been clicked.

Notes about adding, removing and configuring stacks:

  1. A single, default Board layer stack is defined when a new board is created. Note that this stack cannot be deleted but it can be renamed in the Advanced section of the dialog.
  2. When the Add Stack button is clicked, the currently selected stack is duplicated and added to the right of the selected stack. After adding a new stack, set its Name and other properties as required in the Stack Properties region of the dialog.
  3. Layer properties apply to the entire layer, across all stacks of which the layer is a member. Note that separate Solder Mask/Coverlay and Overlay layers can be added for each stack if required using the Add Layer button. 
  4. The order of the stacks, from left to right, can be changed using the Move Left and Move Right buttons at the bottom-right of the stack region. Note that the order that the stacks are shown in the Layer Stack Manager does not dictate how they are used in the board design.
  5. Each stack should be named to uniquely identify it; this helps ensure the correct stack is applied to each user-defined board region.
  6. Each stack that is flexible must have its Flex option enabled, so that required flex bending properties can be applied. Note that flex bending is defined by placing a Bending Line across the flex region (Design » Board Shape menu), refer to the Defining Board Regions and Bending Lines article for more information.

When you click on the cell associated with a particular layer in the layer region of the Layer Stack Manager, that layer will be highlighted in the graphical display of the currently selected stack (to the left) and also across all defined stacks that use that layer in the stack region of the dialog.

Adding and Removing Layers from a Stack

Layers are added, removed, and re-ordered in the upper half of the Layer Stack Manager using either the Add Layer button (for adding) or the right-click menu (for all types of changes).

Notes about adding, removing and moving layers:

  1. To add a new layer, click the Add Layer button then choose the type of layer to add (signal layer, internal plane, dielectric, or overlay).
  2. New layers are added into the set of layers listed in the upper region of the Layer Stack Manager. By default a newly-added layer is enabled for use across all existing stacks. Select each stack in turn in the lower region of the dialog then disable the layer if it is not required in that stack using the checkbox to the left of the layer's name in the upper region.
  3. Note that this behavior (to automatically add a layer to all stacks) does not occur if Solder Mask/Coverlay and Overlay layers are added. These layer types can be added/removed to each stack.  To do this, first select the required stack. If a stack already has Solder Mask/Coverlay and Overlay layers enabled, the relevant Add commands will be grayed out (not available).
  4. Initially, when a copper layer (signal or plane) is added, a dielectric layer is automatically also added maintaining the symmetry of the stack (copper-dielectric-copper-dielectric, etc.). The location and type of dielectric that is added is controlled by the technology style setting using the drop-down located at the top-right of the dialog. This is not the case if the style option is set to Custom. In this case, only the chosen layer type is added (more details on the style setting below).
  5. To move a layer up or down in the stack, right-click on the layer and select the Move Layer Up or Move Layer Down command, or use the Move Up or Move Down buttons. Note that when a copper or dielectric layer is moved the adjacent dielectric/copper layer will also move unless the style option is set to Custom; then only the selected layer will move.
  6. Layer Properties apply to the entire layer across all stacks of which the layer is a member. This does not apply to Solder Mask/Coverlay and Overlay layers that have been selectively added to a stack.
  7. One or more layers can be selected and deleted. A deleted layer is removed from the set of available layers and therefore, is removed from all stacks currently using it.
  8. Use the  (Undo) and  (Redo) buttons to roll layer stack changes backward or forward.
The Layer Stack Manager includes an drop-down at the top-right of the dialog for selecting the style of layer technology to be used on the board. The available options include: Layer Pairs, Internal Layer Pairs, Build-Up and Custom. Note that this option does not affect the final design of the layer stackup. It is used to help select the appropriate type of dielectric layer to add and the location in the stack where it is added when you run an Add Layer command. In all modes other than Custom, whenever a signal layer is added, a dielectric layer will also be added. The type and location of dielectric added depends on the current number of layers used and the current style setting. Note that once a second layer stack has been added, the style is automatically set to Custom. In Custom mode, new layers are added one-by-one.

Saving and Loading a Layer Stack

Layer stacks can be saved and loaded using the relevant buttons at the top of the Layer Stack Manager. You have the ability to control how the layers will be added (controlling how the two stacks are merged) to arrive at your desired stack setup.

In addition, if you are connected to a server, you have the ability to save your layer stack as a managed item in that server, and load a stack from a server. By extension, if your company is using environment configuration management, layer stack usage can be managed through that system, allowing the use of all or specific layer stack items stored in the server and shared with the defined role(s).

As well as merging the set of layers defined in the Stackup file with the existing set of layers, layer stacks defined in the external Stackup file are also imported.

Saving a Layer Stack

Click the Save button at the top-left of the Layer Stack Manager dialog to:

  • Save to File - save the layer stack into a stack-up file (*.stackup).
  • Save to server- save the layer stack data into a revision of a target layer stack Item in a target server.

Loading a Layer Stack

Click the Load button at the top-left of the Layer Stack Manager dialog, to:

  • Load From File - load a layer stack that has previously been saved to a stack-up file (*.stackup).
  • Load From server - load layer stack data from a revision of a target layer stack Item in a connected server.
The Load button's menu will also present the available (and shared) Layer stack Items in the server for which you are currently signed in.

Merging Layer Stacks

When you load layer stack data, from a *.stackup file or a Layer stack Item in a server - the Merge Layer Stacks dialog will open. This dialog is used to control how the current layers are to be merged with the layers in the stack being loaded.

Existing layer and layer data is merged with the layers being loaded.
Existing layer and layer data is merged with the layers being loaded.

The New Layer column corresponds to the layer stack being loaded/imported, while the Old Layer column corresponds to the existing, current layer stack for the board. The Used column shows which layers currently have primitives placed on them in the board design. Use the Create column to specify that an imported layer be used (checked) or not (unchecked).

The Action column details what is to be done for the associated layer:

  • Move Primitives - the layer being loaded will be used and existing primitives on the current layer will be moved to that layer.
  • Add - this is not a layer in the current stack; it will be added to the stack.
  • Skip - not a layer in the current stack; it will not be added to the stack.
  • Skip & Delete - this layer exists in the current stack but is no longer required. Do not import the layer from file/server item, and delete the existing layer from the stack.
  • Delete - delete this layer.

The default state for the dialog is to:

  • Map existing layers (those used in the board's current layer stack).
  • Add new layers - found in the layer stack being loaded.
  • Add all layers that are currently being used in the board design (i.e. have primitives placed upon them).

If you have a layer that is in the current stack but not in the new stack, it will not be removed. In addition, primitives are not deleted, but rather moved to the newly created layer. If you disable the creation of a layer and that layer is used and has primitives on it, you will be alerted to this and asked to confirm.

There also is validation, for example, actions such as mapping a mechanical layer to a signal layer cannot be performed.

Ordering of the layers is consistent with the ordering presented in the Layer Stack Manager dialog, with all mechanical layers appearing after the physical layers.

The grid supports familiar grouping, sorting and filtering. In addition, multiple Create column checkboxes can be controlled using commands on the right-click context menu.

Configuring the Layer Properties

The properties of each layer must be completely defined and should be done in consultation with the PCB fabricator. This information is included in the Layer Stack Table – the properties of each layer are edited directly in the Layers region of the dialog. To edit a cell, double-click on it – if that cell supports editing, it will become available for editing.

Multi-cell editing is supported with the following:

  • Use the Windows standard Shift+Click (for a range) or Ctrl+Click (for individual cells) to select multiple cells.
  • Press F2 to enter editing mode (do not use the mouse – you will loose your selection).
  • Use the keyboard to type the required string or use the mouse to select the required option from a drop-down.
  • For checkboxes, Shift+Click or Ctrl+Click in the cell around the checkbox then press the Spacebar to toggle the setting of the selected checkboxes.

Layer Types, Properties and Function

In Altium NEXUS, there is a single set of layers defined and any layer can then be used in any layer stack. This set of layers includes all of the layers that are used in the overall PCB design regardless of whether the design is a single PCB or a rigid-flex design incorporating numerous rigid and flex sections. A variety of types of layers can be included in the layer stack: copper, dielectric, surface finish and mask layers. Each layer must be completely specified in terms of its material and mechanical requirements including the material used, the thickness, the dielectric constant, etc. The selection of materials and their properties should always be done in consultation with the board fabricator.

The layer types and their properties are detailed in the table below:

Layer Type Material Thickness Properties to Define Comments
Signal Copper

mm or mils

Thickness

Copper layer used to define signal routing, carries the electrical signals and circuit supply current. Typically annealed foil and electro-deposited.
Internal Plane Copper mm or mils Thickness Solid copper layer used to distribute power and ground; can be split into regions. Also must specify the distance from the plane edge to the board edge (pullback). Typically annealed foil.
Dielectric Varies, including: FR4, polyimide, and a variety of manufacturer-specific materials offering different design parameters mm or mils

Type (function), Material, Thickness and Dielectric Constant (Dk).

Insulating layer; can be rigid or flexible. Used to define core, prepreg and flexible layers.

Important mechanical properties are: including dimensional stability over moisture and temp ranges, tear resistance, and flexibility.

Important electrical properties include insulation resistance, dielectric constant (Dk), and dissipation factor (loss tangent, Df or Dj)

Overlay Screen printed epoxy, LPI (liquid photo-imageable)     Present text/artwork, such as component designators.

Solder Mask/Coverlay

1) Liquid photo-imageable solder mask (LPI or LPSM) , Dry Film photo-imageable Solder Mask (DFSM)

2) Adhesive coated flexible film, typically polyimide or polyester.

mm or mils Type (function), Material, Thickness and Dielectric Constant (Dk).

1) Protective layer that restricts where solder can be applied to the circuit. A cost effective and proven technology, suitable for rigid and flex use class A (flex-to-install) applications. Suitable for finer features than flexible film coverlay.

2) Suitable for flex use classes A and B (dynamic flex). Requires rounded holes/corners, which are typically drilled or punched.

Paste Mask Layer from which a paste mask stencil is fabricated. Stencil is typically stainless steel. Openings in the stencil define locations where solder paste is to be applied to the component pads prior to component placement.     Mask layer used to fabricate solder mask screen, which defines locations where solder paste is to be applied.

Assigning a Net to a Plane Layer

With multiple layer stacks, the net is always assigned to the plane by double-clicking on the plane layer in the workspace (the plane layer must be the active layer).

When you double-click on a split plane area the Split Plane dialog will open. Select the required net. This process is the same if you are assigning a single net to the entire plane, or are assigning a net to a split region of the plane.

To assign a net to a plane layer, make the plane layer the active layer then double-click to open the Split Plane dialog to assign the net.
To assign a net to a plane layer, make the plane layer the active layer then double-click to open the Split Plane dialog to assign the net.

Defining the Overall Board Shape

Main Article: Defining the Board Shape

Regardless of the final make-up of the board (single rigid area or multiple rigid-flex sections), the overall outer shape is defined as the Board Shape.

The Board Shape can be:

  • Defined manually - by redefining the shape or moving the existing board vertices (corners). Switch to Board Planning Mode (View » Board Planning Mode) then use the commands in the Design menu.
  • Defined from selected objects - typically done from an outline on a mechanical layer. Use this option if an outline has been imported from another design tool. Switch to 2D Layout Mode (View » 2D Layout Mode) then use the command in the Design » Board Shape sub-menu.
  • Defined from a 3D body - use this option if the blank board has been imported as a STEP model from an MCAD tool into a 3D Body Object (Place » 3D Body). Switch to 3D Layout Mode (View » 3D Layout Mode) then use the command in the Design » Board Shape sub-menu to select the board shape.

The main View menu has a cluster of PCB editor working modes with easy to remember shortcuts, allowing you to quickly switch between Board Planning Mode (1), 2D Layout Mode (2), and 3D Layout Mode (3). The editor menus will populate with relevant commands for each of the respective modes. If you are used to finding your favorite board shape command on the Design menu and do not see it, make sure you are in the right mode!

Defining a Board Region and Assigning a Sub-Stack

Main Article: Defining Board Regions and Bending Lines

The board is split into regions and stacks are assigned in Board Planning Mode.
The board is split into regions and stacks are assigned in Board Planning Mode.

  • You divide a board into multiple regions by placing split lines. This is done with the PCB editor in Board Planning Mode (View » Board Planning Mode, shortcut: 1). Place a split line via the Design » Define Split Line command.
  • A split line must run from an outer edge to an outer edge, and can be adjusted after it has been placed.
  • Each region is named and assigned a layer stack in the Board Region dialog. The easiest way to do this is to work in Board Planning Mode - where you can double click on the region of interest to open the Board Region dialog.
  • Note that the layer stacks are named in the Layer Stack Manager when it is in Advanced mode.

Managed Stacks and Embedded Components

Related article: Embedded Components

When you embedded a component, Altium NEXUS has to manage how that embedded component affects the layer stack not only in terms of how it is displayed, but also in terms of calculated data such as solder mask openings and design rule checking. It does this by creating a stack for each unique combination of placed + cut layers needed by the various embedded components included in the design. These stacks are referred to as Managed Stacks.

The Managed Stack is created automatically when a component is embedded within the layers of the board. As managed stacks are created automatically, there is no user-input needed in their creation and management. Altium NEXUS checks for embedded components, tests if any of the current managed stacks are suitable and if not, creates a new one. The same applies when embedded components are removed; if a managed stack is no longer needed, it is automatically removed. To force Altium to check if new managed stacks are needed, switch between 2D and 3D Layout Modes.

The Managed Stack defines the board structure in the vertical, of Z plane. In the horizontal, or X Y plane, the region that the stack extends over is defined by the cavity definition built into that embedded component.

Note that the stack selector on the bottom of the dialog is set to Show Managed Stacks. When this is selected, the dialog displays the managed stack. Note that the stack selector setting is not persistent and when the dialog is reopened, it defaults to Show User Stacks.

Documenting the Layer Stack

Documentation is a key part of the design process and is particularly important for designs with a complex layer stack structure, such as a rigid-flex design. To support this, Altium NEXUS includes a Layer Stack Table, which is placed (Place » Layer Stack Table) and positioned alongside the board design in the workspace. The information in the layer stack table comes from the Layer Stack Manager dialog.

Altium NEXUS also provides a dedicated documentation editor - Draftsman. Draftsman has been built from the ground up as an environment for creating high-quality documentation that can include dimensions, notes, layers stack tables, and drill tables. You can either continue to create documentation using the approaches described here, or explore the documentation capabilities of Draftsman.

Include a Layer Stack Table in the design documentation.
Include a Layer Stack Table in the design documentation.

The Layer Stack Table is an intelligent design object, meaning it can be placed and updated as the design progresses. 

Placing a Layer Stack Table

To fully document the layer stack, place a Layer Stack Table (Place » Layer Stack Table). The Layer Stack Table details the layers, material, thickness, and dielectric constant. 

When the command is launched:

  1. A Layer Stack Table will appear floating on the cursor, ready to be placed into the workspace onto the active layer.
  2. Click to place the Layer Stack Table.
  3. Double-click anywhere on the placed table to open the Properties panel in Layer Stack Table mode.

The Layer Stack Table details the:

  • Layers used in the design
  • Material used for each layer
  • Thickness of each layer
  • The Dielectric Constant
  • The name of each stack and the layers used in that stack

The Layer Stack Table can also include an optional map of the PCB. This is an outline of the board showing how the various layer stacks are assigned to regions of the board. Use the Show Board Map option and slider bar to configure the settings desired.

Configuring the Drill Pairs

In a design with multiple layer stacks, the Drill Pairs are defined for each stack. Drill pairs are configured in the Layer Stack Manager.

To define the drill pairs:

  1. Select the stack in the lower part of the Layer Stack Manager.
  2. Click the Drill Pairs button to open the Drill-Pair Manager.
  3. Define the drill pairs for that stack, as required.
  4. Repeat the process for each stack in the design.

Including a Drill Table

Main Article: Drill Table object

Altium NEXUS includes an intelligent Drill Table that is placed like any other design object. The table displays the drills required for a specified layer pair, you will need to place a drill table for each layer pair used in the design.

Altium NEXUS also provides a dedicated documentation editor - Draftsman. Draftsman has been built from the ground up as an environment for creating high-quality documentation that can include dimensions, notes, layers stack tables, and drill tables. You can either continue to create documentation using the approaches described here or explore the documentation capabilities of Draftsman.

If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.
Content