Contact Us
Contact our corporate or local offices directly.
Parent category: Violations Associated with Nets
Default report mode:
This violation occurs when a wire object is detected to be floating, i.e. not electrically connected to any part of the circuit design.
If compiler errors and warnings are enabled for display on the schematic (enabled on the Schematic - Compiler page of the Preferences dialog), an offending object will display a colored squiggle beneath it. Hovering over the object will display a pop-up hint that summarizes the violation. A notification is also displayed in the Messages panel in the following format:
Unconnected line <
Location1> To
<Location2>
where:
Ensure that the offending wire object is connected into the circuit as required. If the wire is redundant, delete it from the design. If the wire (or any other object) is off the sheet and cannot be directly selected, use the Edit » Select » Outside Area command to select it, then delete it.
Contact our corporate or local offices directly.