Altium NEXUS Documentation

Drag

Modified by Tiffany Cullen on Aug 13, 2019
このページは、サポート対象外となったAltium Vaultについて紹介しています。Altium Vaultとそのコンポーネント管理機能は Altium Concord Proに移行しました。

Parent page: Schematic Commands

The following pre-packaged resources, derived from this base command, are available:


Applied Parameters: Action=SingleObject

Summary

This feature is used to drag a single placed electrical object in the current document, while maintaining connectivity with other electrical objects.

Access

This command is accessed from the Schematic Editor by holding the Ctrl key down while clicking and dragging an electrical object in the workspace.

Use

Position the cursor over the required object you wish to drag, hold the Ctrl key down, then click on the object and drag to its required new location. As you start to drag, the Ctrl key can be released if you wish. Once in the new position, simply release the mouse button to effect placement.

The following additional actions can be performed while dragging the object:

  • Press the Spacebar (or Shift+Spacebar) to change the wiring mode for any connected wires, buses, or signal harnesses.
  • Press Ctrl+Spacebar to rotate the object counterclockwise and in increments of 90°. Press Shift+Ctrl+Spacebar to rotate the object clockwise.
  • Press the X or Y keys to flip the object along the X-axis or Y-axis respectively.
  • Hold the Alt key to constrain the direction of movement to the horizontal or vertical axis, depending on the initial direction of movement.

Tips

  1. The object doesn't need to be selected in order to use this feature.
  2. If the object is locked, a dialog will appear, asking you to confirm that you wish to continue - click Yes to do so. In this case, the object will appear floating on the cursor, simply position as required, then click, or press Enter, to effect placement.
  3. The wiring mode for connected wiring can only be changed provided the Drag Orthogonal option is enabled, on the Schematic - General page of the Preferences dialog. The default mode is to keep wiring at 90 Degree angles. If this option is disabled, not only can the wiring mode not be cycled, the connected wiring will be repositioned obliquely.
  4. By default, the Ctrl key must be held down when you click and drag, to perform a drag (and maintain connectivity). If you simply click and drag on an object without holding the Ctrl key first, you will perform a move (and connectivity will not be maintained). This default behavior can be controlled using the Always Drag option, on the Schematic - Graphical Editing page of the Preferences dialog. When enabled, you can then click and drag (without Ctrl) to perform a single object drag. Conversely, to move, rather than drag, you would then need to hold the Ctrl key down first.


Applied Parameters: Action=MultipleObjects

Summary

This command is used to drag chosen placed electrical objects (not simultaneously) in the current document, while maintaining connectivity with other electrical objects.

Access

This command can be accessed from the Schematic Editor by:

  • Choosing the Edit » Move » Drag command from the main menus.
  • Locating and using the Drag command () on the Active Bar.
If the command has been recently used from the Active Bar, it will become the active/visible button. Where other commands are available, this is indicated by a triangle at the bottom-right corner of the button. Click and hold on the active button to access a menu of all associated commands for that grouping.

Use

After launching the command, the cursor will change to a cross-hair and you will be prompted to choose an object to drag. Simply position the cursor over the electrical object that you wish to drag and click, or press Enter. The object will appear floating on the cursor. Simply position the object at its required new location and click, or press Enter, to effect placement.

Continue to select other objects to drag, or right-click, or press Esc, to exit.

The following additional actions can be performed while dragging the object:

  • Press the Spacebar (or Shift+Spacebar) to change the wiring mode for any connected wires, buses, or signal harnesses.
  • Press Ctrl+Spacebar to rotate the object counterclockwise and in increments of 90°. Press Shift+Ctrl+Spacebar to rotate the object clockwise.
  • Press the X or Y keys to flip the object along the X-axis or Y-axis respectively.
  • Hold the Alt key to constrain the direction of movement to the horizontal or vertical axis, depending on the initial direction of movement.

Tips

  1. If the object is locked, a dialog will appear, asking you to confirm that you wish to continue - click Yes to do so.
  2. The wiring mode for connected wiring can only be changed provided the Drag Orthogonal option is enabled, on the Schematic - General page of the Preferences dialog. The default mode is to keep wiring at 90 Degree angles. If this option is disabled, not only can the wiring mode not be cycled, the connected wiring will be repositioned obliquely.


Applied Parameters: Action=SelectedObjects

Summary

This command is used to drag selected electrical objects in the current document, while maintaining connectivity with other electrical objects.

Access

This command can be accessed from the Schematic Editor by:

  • Choosing the Edit » Move » Drag Selection command from the main menus.
  • Locating and using the Drag Selection command () on the Active Bar.
If the command has been recently used from the Active Bar, it will become the active/visible button. Where other commands are available, this is indicated by a triangle at the bottom-right corner of the button. Click and hold on the active button to access a menu of all associated commands for that grouping.

Use

First, ensure that the electrical objects to be dragged are selected in the main design workspace.

After launching the command, the cursor will change to a cross-hair and you will be prompted to choose a reference point by which to hold the selection when dragging. Simply position the cursor over the required position and click, or press Enter. The selected objects will appear floating on the cursor. Simply position the selection at its required new location and click, or press Enter, to effect placement.

The following additional actions can be performed while dragging the selection:

  • Press the Spacebar (or Shift+Spacebar) to change the wiring mode for any connected wires, buses, or signal harnesses.
  • Press Ctrl+Spacebar to rotate the selection counterclockwise and in increments of 90°. Press Shift+Ctrl+Spacebar to rotate the selection clockwise.
  • Press the X or Y keys to flip the selection along the X-axis or Y-axis respectively.
  • Hold the Alt key to constrain the direction of movement to the horizontal or vertical axis, depending on the initial direction of movement.

Tips

  1. If an object in the selection is locked, a dialog will appear, asking you to confirm that you wish to continue - click Yes to do so.
  2. The wiring mode for connected wiring can only be changed provided the Drag Orthogonal option is enabled, on the Schematic - General page of the Preferences dialog. The default mode is to keep wiring at 90 Degree angles. If this option is disabled, not only can the wiring mode not be cycled, the connected wiring will be repositioned obliquely.

 

Found an issue with this document? Highlight the area, then use Ctrl+Enter to report it.

お問合せ

お近くの営業所にお問合せください。

You are reporting an issue with the following selected text
and/or image within the active document:
Altium Designer 無償評価版
Altium Designer 無償評価版
Altium Designerを使用していますか?

弊社の営業担当より詳細情報をご案内しますので、アルティウムジャパン までお問い合わせください。.
Copyright © 2019 Altium Limited

評価版ライセンスが必要な理由を下記から選択してください。

弊社の営業担当より詳細情報をご案内しますので、アルティウムジャパン までお問い合わせください。.
Copyright © 2019 Altium Limited

その場合、評価版ライセンスは不要です。

ボタンをクリックして、最新のAltium Designerインストーラをダウンロードしてください。

Altium Designerインストーラをダウンロードする

弊社の営業担当より詳細情報をご案内しますので、アルティウムジャパン までお問い合わせください。.
Copyright © 2019 Altium Limited

Altium Designerの新規ライセンスのお見積もりをご希望の場合、下記のフォームに入力してください。

プライバシーポリシーに同意の上、[ダウンロード]をクリックしてください。ご登録いただきましたメールアドレスにメールマガジンが送信されます。メール配信の停止は、メール内の​通知設定​​でお手続きいただけます。

Altium Designerサブスクリプションをご利用中の場合、評価版ライセンスは不要です。

お客様がAltium Designerサブスクリプションの有効なメンバーではない場合、下記のフォームに入力して無償評価版をダウンロードしてください。

プライバシーポリシーに同意の上、[ダウンロード]をクリックしてください。ご登録いただきましたメールアドレスにメールマガジンが送信されます。メール配信の停止は、メール内の​通知設定​​でお手続きいただけます。

Altium Designerを評価する理由を下記から選択してください。

弊社の営業担当より詳細情報をご案内しますので、アルティウムジャパン までお問い合わせください。.
Copyright © 2019 Altium Limited

無償評価版を使用するには、下記のフォームに入力してください。

プライバシーポリシーに同意の上、[ダウンロード]をクリックしてください。ご登録いただきましたメールアドレスにメールマガジンが送信されます。メール配信の停止は、メール内の​通知設定​​でお手続きいただけます。

Great News!

Valid students can get their very own 6-month Altium Designer Student License for FREE! Just fill out the form below to request your Student License today.

プライバシーポリシーに同意の上、[ダウンロード]をクリックしてください。ご登録いただきましたメールアドレスにメールマガジンが送信されます。メール配信の停止は、メール内の​通知設定​​でお手続きいただけます。

その場合、Altium Designerビューワーの無償ライセンス(有効期間6か月)をダウンロードできます。

下記のフォームに入力してライセンスをリクエストしてください。

プライバシーポリシーに同意の上、[ダウンロード]をクリックしてください。ご登録いただきましたメールアドレスにメールマガジンが送信されます。メール配信の停止は、メール内の​通知設定​​でお手続きいただけます。

素晴らしいですね。アルティウムではモノづくりに最適なプログラムを提供しています。

Upverterは、コミュニティ主導型の無償プラットフォームで、お客様のような作り手の要求に合わせて設計されています。

試してみる場合、こちらをクリック してください。

弊社の営業担当より詳細情報をご案内しますので、アルティウムジャパン までお問い合わせください。.
Copyright © 2019 Altium Limited

その場合、Altium Designerビューワーの無償ライセンス(有効期間6か月)をダウンロードできます。

下記のフォームに入力してライセンスをリクエストしてください。

プライバシーポリシーに同意の上、[ダウンロード]をクリックしてください。ご登録いただきましたメールアドレスにメールマガジンが送信されます。メール配信の停止は、メール内の​通知設定​​でお手続きいただけます。