WorkspaceManager_Err-MismatchedPinVisibilityMismatched Pin Visibility_AD

您正在阅读的是 18. 版本。关于最新版本,请前往 WorkspaceManager_Err-MismatchedPinVisibility((Mismatched Pin Visibility))_AD 阅读 21 版本
 

Parent category: Violations Associated with Components

Default report mode:

Summary

This violation is related to the power pins (VCC and GND) of a multi-part component. Typically, these pins are associated to part 0, are automatically connected to the VCC and GND nets for the design, and are hidden. If, for one of the component parts, you enable visibility of such a pin, it is no longer connected to the target power net and the error will be flagged.

Notification

If compiler errors and warnings are enabled for display on the schematic (enabled on the Schematic - Compiler page of the Preferences dialog), an offending object will display a colored squiggle beneath it. Hovering over the object will display a pop-up hint that summarizes the violation. A notification is also displayed in the Messages panel in the following format:

Pin is visible in one sub-part and hidden in another sub-part

Recommendation for Resolution

Either disable display of the offending power pin(s) in the workspace or, if keeping the pins displayed, ensure that a VCC and/or GND power port object is attached to the pin(s) accordingly.

Tip

  • Object hints will only appear provided the Enable Connectivity Insight option is enabled on the System - Design Insight page of the Preferences dialog. Use the controls associated with the Object Hints entry in the Connectivity Insight Options region of the page to determine the launch style for such hints (Mouse Hover and/or Alt+Double Click). 
If you find an issue, select the text/image and pressCtrl + Enterto send us your feedback.

软件的功能取决于您购买的Altium产品级别。您可以比较Altium Designer软件订阅的各个级别中包含的功能,以及通过Altium 365平台提供的应用程序所能实现的功能。

如果您在软件中找不到某个讨论过的功能,请联系Altium销售团队以获取更多信息。

Content