Query_Lang-PCBFunctions_Fields_HoleSizeHoleSize_AD

This document is no longer available beyond version 21. Information can now be found here: HoleSize for version 24

Parent page: PCB Query Functions - Fields

Summary

Returns all pad and via objects whose Hole Size property complies with the Query.

Syntax

HoleSize : Number

Number will follow the measurement units currently employed for the document – either Imperial (mil; 1mil = 0.001inch) or Metric (mm; 1mm = 0.001meter).

A specific option for the measurement unit can be specified – overriding the default units specified at the document level – through use of an additional measurement unit-based keyword:

  • AsMils(HoleSize) : Number – to specify a hole size in mil.
  • AsMM(HoleSize) : Number – to specify a hole size in mm.

Example Usage

HoleSize = 16
Returns all pad and via objects that have a Hole Size property which is 16 current measurement units.

HoleSize >= 0.508
Returns all pad and via objects that have a Hole Size property which is greater than or equal to 0.508 current measurement units.

AsMils(HoleSize) Between 12 And 32
Returns all pad and via objects that have a Hole Size property which is greater than or equal to 12mil and less than or equal to 32mil.

AsMM(HoleSize) < 1.016
Returns all pad and via objects that have a Hole Size property which is less than 1.016mm.

Tips

  1. The Hole Size property is only defined for pad and via objects.
  2. This function is an alias for the HoleDiameter and Hole functions.

 