High Speed - Maximum Via Count

Now reading version 17.0. For the latest, read: High Speed - Maximum Via Count for version 21
Applies to Altium Designer versions: 16.0, 16.1, 17.0 and 17.1
 

Rule Category: High Speed

Rule Classification: Unary

Summary

This rule specifies the maximum number of vias permitted for each individual net in the current design.

Use appropriate rule scoping to target a specific net (or collection of nets), using query expression keywords such as InNet, InNetClass, or In AnyNet.

Constraints

Default constraints for the Maximum Via Count rule.

Default constraints for the Maximum Via Count rule.

  • Maximum Via Count - the maximum number of vias permitted in each individual net falling under the defined scope of the rule.

How Duplicate Rule Contentions are Resolved

All rules are resolved by the priority setting. The system goes through the rules from highest to lowest priority and picks the first one whose scope expression matches the object(s) being checked.

Rule Application

Online DRC and Batch DRC.

Note

The features available depend on your level of Altium Designer Software Subscription.

Content