Summary

Returns all fill, original dimension, and track objects whose X2 property complies with the Query.

Syntax

X2 : Number

Number will follow the measurement units currently employed for the document – either Imperial (mil; 1mil = 0.001inch) or Metric (mm; 1mm = 0.001meter).

A specific option for the measurement unit can be specified – overriding the default units specified at the document level – through use of an additional measurement unit-based keyword:

  • AsMils(X2) : Number – to specify a value in mil.
  • AsMM(X2) : Number – to specify a value in mm.

Example Usage

X2 = 1200
Returns all fill, original dimension, and track objects that have a X2 property which is equal to 1200 current measurement units.

X2 >= 38.1
Returns all fill, original dimension, and track objects that have a X2 property which is greater than or equal to 38.1 current measurement units.

AsMils(X2) Between 1000 And 1400
Returns all fill, original dimension, and track objects that have a X2 property which is greater than or equal to 1000mil and less than or equal to 1400mil.

AsMM(X2) < 20.32
Returns all fill, original dimension, and track objects that have a X2 property which is less than 20.32mm.

Tips

  1. The X2 property is only defined for fill, original dimension, and track objects.

 

Found an issue with this document? Highlight the area, then use Ctrl+Enter to report it.

Contact Us

Contact our corporate or local offices directly.

We're sorry to hear the article wasn't helpful to you.
Could you take a moment to tell us why?
200 characters remaining
You are reporting an issue with the following selected text
and/or image within the active document: