お問合せ
お近くの営業所にお問合せください。
Parent page: Part
Schematic Editor object properties are definable options that specify the visual style, content, and behavior of the placed object. The property settings for each type of object are defined in two different ways:
Pre-placement settings – most Part object properties, or those that can logically be pre-defined, are available as editable default settings on the Schematic - Defaults page of the Preferences dialog (access from the button at the top-right of the design space). Select the object in the Primitive List to reveal its options on the right.
Post-placement settings – all Part object properties are available for editing in the Properties panel when a placed Part is selected in the design space.
Standard
- components that possess standard electrical properties, are always synchronized between the schematic and PCB (the footprint, pins/pads, and net assignments must all match), and are included in the BOM. An example is a standard electrical component, such as a resistor.Mechanical
- components that do not have electrical properties, are not synchronized (you must manually place them in both editors), and are included in the BOM. An example is a heatsink.Graphical
- components that do not have electrical properties are not synchronized (you must manually place them in both editors), and are not included in the BOM. An example is a company logo.Net Tie (In BOM)
- components that are used to short two or more different nets together, are always synchronized between the schematic and PCB (the footprint, pins/pads, and net assignments must all match), and are included in the BOM. They differ from a Standard component in that connectivity created by copper within the footprint is not checked; it is this copper that allows the nets to be shorted. Note: enable the Verify Shorting Copper option in the Design Rule Checker dialog to verify that there is no unconnected copper within the component.Net Tie (No BOM)
- components that are used to short two or more different nets together, are always synchronized between the schematic and PCB (the footprint, pins/pads, and net assignments must all match), and are not included in the BOM. They differ from a Standard component in that connectivity created by copper within the footprint is not checked; it is this copper that allows the nets to be shorted. Note: enable the Verify Shorting Copper option in the Design Rule Checker dialog to verify that there is no unconnected copper in the component.Standard (No BOM)
- components that possess standard electrical properties, are always synchronized between the schematic and PCB (the footprint, pins/pads, and net assignments must all match), and are not included in the BOM. An example is a testpoint component that you want to exclude from the BOM.Jumper
- components that are used to include wire links in a PCB design, for example, on a single-sided PCB that cannot be fully routed on one layer. For this component type, the component footprint and pins are synchronized between the schematic and PCB but the net assignments are not, and the component is included in the BOM. As well as selecting this option at the component level, both of the pads in the component must have their JumperID set to the same non-zero value. Jumper type components do not need to be wired on the schematic; they only need to be included on the schematic if they are required in the BOM. If they are not required in the BOM, they can be placed directly in the PCB where the Component Type is set, the JumperIDs are set, and the Nets manually assigned for the pads.Revision state - this field displays the current lifecycle state of the selected component revision, with the color icon and name of the revision state.
Up to date
) or not (Out of date
). If the revision is in an inapplicable state (not allowed for use in designs) the entry will display Not applicable
. Click the Component issues - if a selected component sourced from the connected Altium 365 Workspace has any health issues, an indication of this will be presented by the (for errors) or
(for fatal errors) icon. The number at the right of the icon indicates the number of found issues. Click the down arrow at the right of the number to see the short descriptions of the issues.
An example of library health issues found.
0 Degrees
, 90 Degrees
, 180 Degrees
, and 270 Degrees
.Favorites - parameters marked as Favorites will be shown in the Parameters list, while those not marked will be hidden. Hover to the right of a parameter filter’s name and click the icon to set the filter as a Favorite. To remove a parameter as a Favorite, click the icon again.
0°
, 90°
, 180°
, and 270°
.This region lists the Pins and Names for all the pins of the selected component. Use the eye icon to show/hide the pin. Use the lock icon to lock/unlock the pins.
お近くの営業所にお問合せください。